  GE Medical Systems DINAMAP PRO 210: BP, Pulse, IVAC Temp, Printer
  GE Medical Systems DINAMAP PRO 210
 
Bookmark and Share

Our Price: $3,357.80


Product Code: 76

Description
 

Request A No-Obligation In-Office Demonstration Ask A Question About This Product

Gold Standard BP, Predictive Temp and Pulse

The DINAMAP PRO 210 vitals signs monitor offers reliable automated BP, predictive temp and pulse rate using DINAMAP technology that's been clinically-proven as more accurate than competitive models. BP and pulse assessment is fast and easy: with the properly-sized BP cuff in place, press the large gray knob to take a reading. IVAC TurboTemp gives an accurate reading in about 7 seconds or less.

All DINAMAP monitors use an oscillometric stepped deflation pattern to recognize and reject artifact. The gold standard DINAMAP algorithm seeks pulses of equal frequency and amplitude and will only deflate when a proper reading is obtained. DINAMAP rejects bad data so you can trust the first numbers that appear on the screen.

  • Includes BP and pulse rate and is upgradeable to include Masimo SpO2 or Nellcor
  • Covered by a 3-year parts and labor warranty
  • Feature a common user interface

    Blood Pressure
    Blood Pressure Technique:
    Oscillometric measurement of systolic, diastolic and mean arterial pressure and pulse rate.
    Cuff Inflation Adjustment Range:
    Adult/Pediatric: 100 to 250 mmHg; 5 mmHg increments
    Neonate: 100 to 140 mmHg; 5 mmHg increments
    Cuff Pressure Range:
    Adult/Pediatric: 0 to 290 mmHg
    Neonate: 0 to 140 mmHg
    Automatically released if error condition is detected, power fails, or unit is switched off.
    Target Inflation Pressure Range:
    User-selectable cuff inflation pressure
    Adult/Pediatric: nominally 160 mmHG
    Neonate: nominally 110 mmHg
    Determination Time:
    20 seconds to 45 seconds typical
    Adult - 120 secs maximum
    Neonate - 85 secs maximum
    Accuracy:
    Meets or exceeds SP 10-1992 AAMI standards
    Pressure Preset Levels:
    Resolutions of 5 mmHg up to Maximum Adult/Neonate limits
    Systolic Determinations:
    Adult: Max: 245 mmHg; Min: 30 mmHg
    Neonate: Max: 140 mmHg; Min: 40 mmHg
    Diastolic Determinations:
    Adult: Max: 195 mmHg; Min: 10 mmHg
    Neonate: Max: 100 mmHg; Min: 20 mmHg
    MAP Determinations:
    Adult: Max: 215 mmHg; Min: 15 mmHg
    Neonate: Max: 115 mmHg; Min: 30 mmHg
    Operating Modes:
    AUTOMATIC, STAT, MANUAL Modes. Press START/STOP key to cancel.
    Automatic Mode (Blood Pressure) Cycle Time:
    Preset at 3 minutes. User can select blood pressure determination frequency in varied increments between 1 and 120 minutes or operate by manual intervention. The result of the most recent determination will be displayed for up to 90 minutes (AUTO) or 2 minutes (MANUAL).
    Stat Mode:
    Rapid BP determination with early systolic display within 5-minute period.
    Pulse Rate Range:
    Adult/Pediatric: 30 - 200 BPM
    Neonate: 30 200 BPM
    Pulse Rate Accuracy:
    BP±3.5%
    Overpressure Cut-off:
    Adult/Pediatric: 300 - 330 mmHg
    Neonate: 150 - 165 mmHg



    Alarms
    System Alarm Functions:
    Brief alarm test at power turn-on, alarm for no determination and a continuous alarm for microprocessor failure. Audible alarms with diagnostic codes displayed in pulse rate window for system failure.
    Patient Alarm Functions:
    Systolic: Preset at 30 mmHg low and 180 mmHg high
    Diastolic: Preset at 15 mmHg low and 130 mmHg high
    MAP:
    Preset at 50 mmHg low and 140 mmHg high for adult/pediatric and neonate
    Pulse Rate:
    Preset at 40 BPM low and 160 BPM high
    SpO2 Alarm Limits:
    Preset at off (100%) high and 90% low.
    Range: High 51-100% (100% = off)
    Low 50-99%
    Alarm Indicators:
    LED with audio alarm silence key. LED only flashes if audio alarm silenced and an alarm condition exists. Diagnostic data indicated on LCD.



    Trend
    Prior Data:
    Monitor stores 24 hours of data; up to 100 readings within time period.


    Environmental
    Operating Temperatures:
    +41oF to +104oF (+5oC to +40oC)
    Atmospheric Pressure:
    700 to 1060 hPa
    Storage Temperature:
    -4oF to +122oF (-20oC to +50oC)
    Humidity:
    0 to 95% noncondensing



    Power Requirements
    Input Power:
    AC input voltage: 100-240 VAC, 50/60 Hz (nominal) 90-253 VAC, 47-63 Hz (range), 50VA. DC input voltage: 24 VDC, 36VA, supplied from a source conforming to IEC 601-1.
    Fuse:
    AC input is protected by two internal fuses. DC input line is protected by an internal auto-resetting fuse. Battery: 12 volt, 2.3 amp-hours protected by internal auto-resetting fuse.
    Battery:
    Sealed lead acid 12 volt 2.3 amp-hour, minimum operation time of 2 hours (5-minute auto cycle with adult cuff, temperature, SpO2 continuous and printer activated. Longer battery life with vital signs at less frequent intervals). Time for full recharge is 2 hours from full discharge with monitor switched off.
    Low Battery Warning:
    Flashing LED and audio tone alert user of low battery condition.
    Power Cable:
    Domestic: 10-ft, detachable, gray-jacketed, 16-gauge terminated with 3-prong hospital grade plug.
    International: 7.5-ft (2.3m), detachable, black jacketed, 16-gauge terminated with appropriate plug.



    **IVAC Temperature (PRO 200 & PRO 400 only)
    Scale:
    oFahrenheit(F) oCelsius(C)
    RangePredictive mode:
    Max: 42.2o C; 108.0o
    Min: 31.6o C; 88.9o F
    Monitor Mode:
    Max: 42.2o C; 108.0o F
    Min: 26.7o C; 80.0o F
    Monitor Mode Accuracy:
    ±0.1oC ±0.2oF (when tested in a calibrated liquid bath; meets ASTM E1112, Table 1, in range specified)
    Predictive Mode Accuracy:
    ±1.0oF ±0.6oC Determination time less than 60 seconds


    Use only IVAC probes and probe covers. The size, shape, and thermal characteristics of the probe covers can affect the performance of the instrument. Inaccurate readings or retention problems may occur unless IVAC probes and probe covers are used.
    **IVAC is a trademark of Alaris Medical, Inc.



    *NELLCOR Pulse Oximetry (SpO2) (PRO 300 & PRO 400 only)
    Accuracy (± 1 Standard Deviation):
    Adult/neonate 70 - 100% ±3.0 digits; under 70% unspecified
    Saturation Range:
    0 - 100%
    Pulse Rate Range:
    20 - 250 BPM
    Pulse Rate Accuracy:
    SpO2, ±3 BPM
    Saturation Pitch:
    Pitch changes with saturation. Volume selectable from off to 9.


    *NELLCOR is a trademark of Mallinckrodt, Inc.


    Physical Dimensions
    Dimensions:
    9.8 in (H) x 9.8 in (W) x 6.9 in (D)
    24.8 cm (H) x 24.8 cm (W) x 17.5 cm (D)
    Weight:
    7.8 pounds; 3.5 kg (including battery)
    Mountings:
    Self-supporting on rubber feet. Pole mountable. Carrying handle recessed into top of monitor.
    Portability:
    Can be hand-carried by the recessed handle. When attached to the 3215 Rolling Stand, the monitor and accessories can be wheeled from patient to patient.



    Printer
    Paper Width:
    1.75 inches
    Writing Method:
    Direct thermal
    Paper
    Environmental requirements:
    Temperature: 100oF (38oC) maximum
    Humidity: 80% maximum



  •  

    Related Products...
    BP-200 Blood Pressure Monitor for Stress Testing GE Medical Systems DINAMAP PRO 410 GE DINAMAP ProCare 420 Monitor PC Based Vital Signs Monitor
    Our Price: $4,495.50
    Add
    Our Price: $5,144.85
    Add
    Our Price: $3,000.00
    Add
    Our Price: $4,114.85
    Add
    BP-200 Blood Pressure Monitor for Stress Testing GE Medical Systems DINAMAP PRO 410 DINAMAP ProCare/CareScape 400: BP, Heart Rate, Temp, Nellcor SpO2 & Printer PC Based Vital Signs Monitor | PC Based EKG
    Welch Allyn Atlas 621 Monitor GE Medical Systems DINAMAP® PRO 310 GE Medical Systems DINAMAP PRO 310 GE DINAMAP ProCare 220 Monitor
    Our Price: $4,170.00
    Call 888-321-1300 for quote!

    Add
    Our Price: $4,676.20
    Add
    Our Price: $4,676.20
    Add
    Our Price: $2,000.00
    Add
    Welch Allyn Atlas 621 Vital Signs Monitor GE Medical Systems DINAMAP PRO 310 GE Medical Systems DINAMAP PRO 310 DINAMAP ProCare 220 Monitor


     Share your knowledge of this product with other customers... Be the first to write a review.